Product of the Month – ProFyre Conventional Smoke & Heat Detectors

3 mins read

This month we will be taking a look at our ProFyre Conventional Smoke and Heat Detectors. This range of detectors is available in four different detection types – optical smoke, rate-of-rise heat, fixed heat and combined smoke and heat. They are all housed in a stylish, low-profile enclosure and provide 360 degree LED indication.

ProFyre Conventional Smoke and Heat Detectors have been designed to complement the ProFyre C8 and C24 conventional fire alarm control panels.

ProFyre C8 and C24 Fire Alarm Control Panels

Approvals and Ratings

This conventional detector range is IP43 rated meaning they are protected from tools and small wires greater than one millimeter and are protected from water spray at less than 60 degrees from vertical.

They are fully approved by the Loss Prevention Certification Board (LPCB) and carry the CE mark – demonstrating that they are safe for use and installation in any European country and that they comply with the Construction Products Regulation (CPR), the Low Voltage Directive (LVD),  the Electromagnetic Compatibility Directive (ECD) and all other pertinent directives.

ProFyre Approvals

Detector Types and Typical Applications

There are four detector types available in the ProFyre Conventional range:

  • Optical Smoke Detector
    ProFyre Optical smoke detectors use a pulsing infrared (IR) LED and photodiode to detect the presence of smoke. When smoke enters the detection chamber its particles cause the infrared light to be scattered onto the photodiode light receptor, triggering the detector to send a signal of fire to the fire alarm control panel.ProFyre Optical Smoke Detectors are best suited for detecting optically dense smoke, such as that produced from fires involving materials such as PVC, Plastic, foam and similar materials.
  • Rate-of-Rise Heat Detector
    ProFyre Rate-of-Rise Heat Detectors sense a rapid rise in temperature using a thermistor arrangement. When a fire occurs the heat it produces enters the detection chamber, when the thermister registers a rapid change in heat, or it reaches 58°C, it sends a signal of fire to the fire alarm control panel.ProFyre Rate-of-Rise Heat Detectors are best suited to environments such as garages and manufacturing facilities where exhaust and chemical fumes may make optical smoke detection unreliable.
  • Fixed Heat Detector
    ProFyre Fixed Heat Detectors  use a single thermistor to sense heat in the detection chamber. An alarm is only triggered once a temperature of 57°C is reached, regardless of how quickly the temperature rises.

    ProFyre Fixed Heat Detectors are best suited to areas with fluctuating temperatures, such as boiler rooms or environments with a particularly high temperature.
  • Combined Smoke and Heat Detector
    ProFyre Combined Smoke and Heat Detectors combine detection technologies from both the optical smoke detector and heat detector.

    ProFyre Combined Smoke and Heat Detectors provide good all-round fire detection and respond well to both smouldering and fast burning fires. They are well suited for areas such as hotel rooms or warehouse loading bays.

ProFyre Conventional Smoke and Heat Detectors


For more information about ProFyre Conventional Smoke & Heat Detectors, or to discuss any of the other products that Eurofyre have to offer, please feel free to get in touch either by phone on +44 (0) 1329 835 024, by email to [email protected] or via the online enquiry form situated on our contact page.

Don’t forget you can follow us on LinkedIn, Twitter, Facebook and Google+ or sign up to our newsletter (in the footer below) to receive all the latest information from Eurofyre.

    Contact Eurofyre

    FireRay Hub Beam Detection in Churches

    21st October 2026

    FireRay Hub Beam Detection in Churches

    Churches and cathedrals are among the most historically and culturally significant buildings in the UK. Alongside their primary role as places of worship, they regularly host weddings, funerals, concerts, community events and visitors, and many also house irreplaceable artefacts, artwork, organs and archives. Many of these buildings are centuries old, listed, and built with substantial […]

    Read Article
    SMS SenTRI Addressable Fire Detection for Student Accommodations

    14th October 2026

    SMS SenTRI Addressable Fire Detection for Student Accommodations

    Student accommodation ranges from traditional university halls of residence to large purpose-built complexes operated by private providers. These buildings typically combine individual bedrooms or studio flats with shared kitchens, lounges, study areas and laundry facilities, and are occupied by large numbers of residents throughout the day and night. Effective fire detection is essential in these […]

    Read Article

    30th September 2026

    SecuriSmoke ASD 2000 for Hospitals

    Hospitals are among the most complex buildings in the built environment, combining wards, operating theatres, diagnostic imaging suites, laboratories, plant rooms, pharmacies and administrative offices within a single site that typically operates around the clock. They accommodate patients with varying levels of mobility, alongside clinical staff, visitors and contractors, often across multiple interconnected buildings of […]

    Read Article
    • FyreLine Linear Heat detection
    • Crisis Emergency Voice Communication
    • Xenos Wireless Fire Detection

    Eurofyre is proud to supply its own brands to the fire detection and safety market. All of our products are high quality, extremely reliable and cost-effective.

    Sales & Technical Support

    Eurofyre Sales and Technical Support

    Accreditations

    ISO 9001
    UKAS Management System
    Fire Industry Association
    British Chamber of Commerce