Esento Eclipse Conventional Fire Alarm Panel

Knowledge Base

Key Features

Esento Eclipse Conventional Fire Alarm Panel
Esento Eclipse Conventional Fire Alarm Panel
Esento Eclipse Conventional Fire Alarm Panel
  • 2–4 zones with dual sounder circuits
  • Twin Wire mode
  • EN54-2 & 4 approved, LPCB certified
  • False alarm management (Type A dependency)
  • Simple keypad control & one-man walk test

Overview

The Esento Eclipse from HAES is an EN54 approved 2–4 zone Conventional/Twin Wire (sav-wire) fire alarm control panel, designed as a dynamic entry-level solution for smaller fire detection installations. It combines a compact steel enclosure, integral power supply, and flexible engineering options in a single wall-mounted unit.

The Esento Eclipse Conventional Fire Alarm Panel is available in 2-zone or 4-zone configurations, each provided with two monitored sounder circuits. Zone circuits can be conventionally wired or switched into Twin Wire (sav-wire) mode via a DIL switch, allowing sounders and beacons to share the same cable pair as detectors and call points, reducing installation time and cost by up to 40%. Twin Wire mode requires special detector bases and polarised call points.

The panel supports a wide range of conventional detectors, including Apollo (Series 65, Orbis), Hochiki CDX, and Nittan Evolution Conventional ranges.

The panel comprises a sheet steel enclosure (IP30, epoxy powder coated) suitable for wall mounting, with a hinged, lockable front door and an optional recessing bezel (FMK-ECL). Cable entry is via 20mm knockouts at the top and rear of the cabinet.

An eight-button keypad with three larger colour-coded buttons — RESOUND (red), SILENCE (blue), and RESET (green) — provides straightforward operation. Controls can be activated via a key switch or a programmable four-digit code. Bright LED indicators show zone fire, fault, disablement, and test status at a glance.

The panel provides common Fire and Fault volt-free relays (3A @ 30Vdc), switched -ve Fire and Fault outputs, class change and alert inputs, and a zone interface function for interconnecting multiple panels.

Programmable features include fire latching options, short-circuit-as-alarm settings, intrinsically safe zone operation, detector removal monitoring, sounder resound behaviour, Type A dependency (false alarm management, LPCB approved), and configurable sounder circuit functions — all accessed through Level 3 engineering codes on the keypad.

Turntable

Approvals

Tech Specs

Enclosure1.2 mm Mild Steel IP30
Cable entry20 mm knockouts located in the top and rear of the cabinet
Dimensions (W x D x H)Back box: 300 x 80 x 250 mm Lid: 308 x 23 x 260 mm
Mains supply1.25 A internal switch mode power supply, Nom 27 V DC
Battery capacity2 x 3.2 Ah 12 V VRSLA
Detection zones2 or 4, EOL = 4K7R
Sounder circuits2 x monitored, fused @500mA, EOL = 4K7R
Twin WireSelectable in panel
On board relays1 x Fire, 1 x Fault, 3 A, 30 V volt free changeover
Outputs1 x Fire, 1 x Fault 40 mA switch -ve outputs
Switch inputsClass change & alert (pulsing)
Intrinsically Safe ModeSelectable per zone
False alarm managementType A dependency mode, approved by LPCB