Using Messenger Wire with Linear Heat Detection

3 mins read

Messenger wire is a secondary, steel wire used to add rigidity to cable. It does not carry any signal but is used to add strength to the cable to prevent sagging when running through the air or to make it easier to fish over long distances in commercial installations. In effect, messenger wire provides a backbone so that the cable carrying the signal is not under any strain.

The most common application of messenger wire that we come across is on telephone poles to carry telephone cable through the air with minimal sagging. However, it can be used to assist almost any kind of cable that requires extra support through the air, including linear heat detection cable.

Using Messenger Wire with Linear Heat Detection

Messenger wire can be combined with any FyreLine Linear heat detection cable to provide extra support where it is needed. Messenger wire is wrapped around the detector at approximately one turn per foot and provides a support wire, designed to simplify the installation of the LHD in areas where mounting is difficult due to the lack of appropriate support structures or mounting surfaces such as applications with high ceilings and large open areas.

FyreLine Linear Heat Detection

The FyreLine linear heat detection system can detect heat anywhere along its length to provide fast and reliable heat detection with accurate location reporting for a variety of applications.

FyreLine is easy-to-install and maintain and is cost effective. FyreLine is available in two versions:

FyreLine Digital Linear Heat Detection

FyreLine Digital

FyreLine Digital is a fixed temperature linear heat detection system available with four different temperature ratings; 68°C, 88°C, 105°C or 185°C. Once FyreLine Digital heat sensing cable reaches its rated temperature, a signal is sent to the fire alarm control panel.

FyreLine Analogue Linear Heat Detection

FyreLine Analogue

FyreLine Analogue heat sensing cable continually monitors for increases in temperature and can, therefore, be configured to provide a pre-alarm as well as a full alarm condition. This provides the ability to investigate potential fires before action is taken. Once the cable reaches its predetermined temperature a signal is sent to the fire alarm control panel to raise the appropriate alert.

How to Install Messenger Wire and LHD Cable?

When using messenger wire with FyreLine linear heat detection cable, turnbuckles and eyebolts must be used each end of a straight to put the support wire under tension. The run between turnbuckles should not exceed 76m (250ft) and the cable should be supported at regular intervals with approved intermediate fasteners. The spacing of intermediate fasteners will largely be determined by the application but should never exceed 15m (50 feet).

When using messenger wire in outside applications, increased detector support must be provided by using additional intermediate fasteners with closer spacing.


For more information about the FyreLine Linear Heat Detection system, or to discuss any of the other products that Eurofyre have to offer, please feel free to get in touch either by phone on +44 (0) 1329 835 024, by email to [email protected] or via the online enquiry form situated on our contact page.

Don’t forget you can follow us on LinkedIn, Twitter and Facebook or sign up to our newsletter (in the footer below) to receive all the latest information from Eurofyre.

    Contact Eurofyre

    SecuriSmoke ASD 2000 for Retail Stores

    28th October 2026

    SecuriSmoke ASD 2000 for Retail Stores

    Retail stores range from small high street shops and convenience stores to large supermarkets, department stores and out-of-town retail warehouses. Beyond the shop floor, many also include stockrooms, loading bays, bakeries, cafés, refrigeration, plant rooms and back-of-house offices, and they welcome large numbers of customers and staff throughout long opening hours. Fire detection plays a […]

    Read Article
    FireRay Hub Beam Detection in Churches

    21st October 2026

    FireRay Hub Beam Detection in Churches

    Churches and cathedrals are among the most historically and culturally significant buildings in the UK. Alongside their primary role as places of worship, they regularly host weddings, funerals, concerts, community events and visitors, and many also house irreplaceable artefacts, artwork, organs and archives. Many of these buildings are centuries old, listed, and built with substantial […]

    Read Article
    SMS SenTRI Addressable Fire Detection for Student Accommodations

    14th October 2026

    SMS SenTRI Addressable Fire Detection for Student Accommodations

    Student accommodation ranges from traditional university halls of residence to large purpose-built complexes operated by private providers. These buildings typically combine individual bedrooms or studio flats with shared kitchens, lounges, study areas and laundry facilities, and are occupied by large numbers of residents throughout the day and night. Effective fire detection is essential in these […]

    Read Article
    • FyreLine Linear Heat detection
    • Crisis Emergency Voice Communication
    • Xenos Wireless Fire Detection

    Eurofyre is proud to supply its own brands to the fire detection and safety market. All of our products are high quality, extremely reliable and cost-effective.

    Sales & Technical Support

    Eurofyre Sales and Technical Support

    Accreditations

    ISO 9001
    UKAS Management System
    Fire Industry Association
    British Chamber of Commerce