Eurofyre’s Product of the Year – FyreLine Analogue Linear Heat Detection System

4 mins read

This year we have featured a different product each month on our website and in our newsletter. But, out of all of our featured products, which one do we think deserves the title of “Product of the Year”? Well, the answer is… Our FyreLine Analogue Linear Heat Detection System.

Linear Heat Detection – A Forgotten Technology

Linear heat detection can provide reliable fire detection across a huge range of applications. Linear heat detection cable can be used in lengths in excess of a kilometer and is capable of detecting excess heat anywhere along its length.

Linear heat detection is extremely cost-effective and can easily be installed alongside, or in place of, traditional or conventional heat detectors. It can operate in areas where traditional type detection may be difficult to install or maintain, is too expensive or unable to provide reliable detection.

Typical applications where linear heat detection can provide superior fire detection include: Cable trays, conveyor belts, fixed roof tanks, tunnels, car parks, escalators, thatched roofs, power stations and many more.

Why Eurofyre Chose FyreLine Analogue Linear Heat Detection System as the Product of the Year?

Eurofyre’s FyreLine Analogue Linear Heat Detection System is:

  • Cost-effective
  • Low-maintenance
  • Easy to install
  • Able to provide detection at the point of risk
  • Self-restorable after detection of fire
  • UL 521 approved and compliant with the EN54:22 draft standard

How does it work?

FyreLine Analogue heat sensing cable is made up of four wires: 2 copper conducting wires, a calibration resistance wire and an average ambient temperature sensor. All four cables are individually coated and twisted together before being wrapped in a foil shield, outer sheath and a protected coating.FyreLine Analogue

When the ambient temperature changes, the resistance of the copper conductors is altered. This change in resistance signals to the fire alarm control panel that the temperature has increased and, once it reaches its predefined temperature, an alarm is signalled. The ability to detect a change in temperature also means that a pre-alarm temperature can be defined, allowing potential fires to be investigated before a full alarm is triggered.

There are a number of different outer coatings available that make the FyreLine heat sensing cable safe for use in a number of different environments. The standard coating used is made from PVC and is suitable for most environments. However, when the cable is exposed to UV or hazardous chemicals, or in environments where the cable may be subject to mechanical abrasion, nylon, polypropylene and stainless steel coatings are available.

Approvals

Approvals

FyreLine Analogue control modules and PVC coated linear heat detection cables carry the CE mark, indicating that they comply with all the applicable directives, including the CPR, EMC and the Low Voltage Directive (LVD). They are also fully approved by the Underwriters Laboratories (UL) and are compliant with EN54:22, the British Standard for Fire Detection and Alarm Systems – Resettable line-type heat detectors.


FyreLine Analogue Heat Detection is a fast reliable and cost-effective fire detection solution for a range of different applications. It is easy to install and can be used in conjunction with, or in place of, conventional detection technologies, where traditional type detectors may be in effective or too expensive.

For more information about FyreLine heat detection systems please feel free to get in touch either by phone on +44 (0)1329 835024 or by email to [email protected] or via the online enquiry form situated on our contact page.

Don’t forget to follow us on LinkedIn, Twitter, Facebook and Google+ or sign up to our newsletter (in the footer below) to receive all the latest information from Eurofyre.

    Contact Eurofyre

    Oggioni DUST Gas Detection in Petrolchemical Plants

    23rd September 2026

    Oggioni DUST Gas Detection in Petrochemical Plants

    Petrochemical plants process, refine and store large volumes of hydrocarbons and other chemical feedstocks, converting raw materials into fuels, plastics, solvents and a wide range of industrial products. These sites typically combine process units, storage tanks, pipelines, loading facilities and control buildings across extensive, often continuously operating, industrial complexes. Given the volume and nature of […]

    Read Article

    17th September 2026

    FyreLine EN54 Fixed Linear Heat Detection: Unaffected by the Weather

    Fire detection systems installed in open, exposed or temporary environments face a challenge that indoor systems rarely have to deal with: the weather itself. Scaffolding can wrap around a live building for months at a time, cable trays and building envelopes sit fully exposed to the elements, and construction sites are, almost by definition, unprotected. […]

    Read Article
    VESDA-E VEP for Superstores

    15th September 2026

    VESDA-E VEP for Superstores

    Superstores are large-format retail environments that combine extensive sales floors with backroom storage, refrigeration plant, loading bays and, in many cases, in-store bakeries, delicatessens and other food preparation areas. They typically operate long trading hours, hold significant stock value and see high footfall from both customers and staff throughout the day. Effective fire detection is […]

    Read Article
    • FyreLine Linear Heat detection
    • Crisis Emergency Voice Communication
    • Xenos Wireless Fire Detection

    Eurofyre is proud to supply its own brands to the fire detection and safety market. All of our products are high quality, extremely reliable and cost-effective.

    Sales & Technical Support

    Eurofyre Sales and Technical Support

    Accreditations

    ISO 9001
    UKAS Management System
    Fire Industry Association
    British Chamber of Commerce