Where to Install Domestic CO Alarms

3 mins read

In order to protect domestic environments from smoke, fire and carbon monoxide, it is essential that alarms are installed correctly. If systems are incorrectly installed, homeowners and their families and pets become at risk of smoke inhalation, carbon monoxide poisoning and death. In particular, knowing where to install CO alarms correctly can make all the difference.

Where to Install Carbon Monoxide (CO) Alarms?

Carbon monoxide (CO) is typically produced by fuel-burning appliances that are faulty or inadequately ventilated and can be found in dwellings such as homes, caravans and boats. Detecting carbon monoxide is impossible without a CO alarm, which will only be able to detect fully if it is properly installed.

CO alarms should be installed within every room holding a fuel-burning appliance, as well as those that are frequently in use, with the most common being kitchens, living rooms, bedrooms and garages.

As well as this, caravans and boats hold a number of other risks from the outside environment as many people use BBQs and generators when camping out, both of which produce gas and carbon monoxide that can easily be drawn into air vents.

Things to Consider

In order to achieve the very best carbon monoxide detection, you must consider the following points when installing a CO alarm:

Ceiling Mount

In rooms with a fuel-burning appliance, such as a fireplace, ensure you place a ceiling-mounted detector at least one to three meters away from the appliance and 300mm from any walls. If there is a partition in the room, ensure the alarm is on the same side as the appliance.

Wall Mount

Where a ceiling mount isn’t feasible, you can use a wall mount. These are very similar to ceiling mounts, however, they must be installed at least 150mm from the ceiling but higher than any window or door to avoid temperature change and increased air flow.

Rooms Without a Burning Appliance

If your room does not contain a burning appliance but is one of the most used rooms in your home, caravan or boat, it is important that a CO alarm is still installed. The CO alarm must be installed close to your breathing zone, such as on a bedside table.

Caravans or Boats

As caravans and boats have adjoining rooms and can be limited on space, it is not always possible to follow guidelines. To overcome this, you should place the CO alarm as far away from appliances as possible, closest to the sleeping area.

Things to Avoid

As well as these considerations, there are also some factors you must avoid, the main being to never install a CO alarm:

  • Where it is blocked by furniture
  • Near a cooking appliance
  • Next to a fan or air vent
  • By a window or door
  • Where temperatures drop to -10°C or exceed 40°C
  • In a dusty environment, as dust may block the sensor
  • In a humid or damp location

Honeywell X-Series Battery Powered CO Alarms


For more information about the Honeywell X-Series Heat, Smoke and CO alarms, or to discuss any of the other products that Eurofyre have to offer, please feel free to get in touch either by phone on +44 (0) 1329 835 024, by email to [email protected] or via the online enquiry form situated on our contact page.

Don’t forget you can follow us on LinkedIn, Twitter, Facebook and Google+ or sign up to our newsletter (in the footer below) to receive all the latest information from Eurofyre.

    Contact Eurofyre

    SMS SenTRI Addressable Fire Detection for Hotels

    2nd September 2026

    SMS SenTRI Addressable Fire Detection for Hotels

    Hotels provide overnight accommodation for guests alongside a wide range of supporting facilities, including restaurants, bars, conference and event spaces, leisure areas, and back-of-house operations such as kitchens, laundries and plant rooms. Many hotels operate around the clock, with guests present at all hours and staff working across multiple departments to keep the building running […]

    Read Article
    VESDA-E VEP for Hotels

    26th August 2026

    VESDA-E VEP for Hotels

    Hotels provide overnight accommodation and hospitality services across a wide range of formats, from boutique city-centre properties and business hotels to large resort complexes with multiple guest wings, function spaces and back-of-house facilities. They combine sleeping accommodation with restaurants, bars, leisure facilities, conference rooms, kitchens, laundries and plant rooms, often operating continuously throughout the day […]

    Read Article
    Wireless Excellence: Your Direct Source for Professional Ajax Systems

    29th July 2026

    Wireless Excellence: Your Direct Source for Professional Ajax Systems

    Wireless fire detection continues to grow in popularity across commercial and municipal buildings, offering a practical alternative to traditional hardwired systems in situations where cabling is difficult, disruptive or costly. As demand for flexible, fast-to-install fire safety solutions increases, manufacturers with a strong background in wireless technology are bringing new levels of reliability and usability […]

    Read Article
    • FyreLine Linear Heat detection
    • Crisis Emergency Voice Communication
    • Xenos Wireless Fire Detection

    Eurofyre is proud to supply its own brands to the fire detection and safety market. All of our products are high quality, extremely reliable and cost-effective.

    Sales & Technical Support

    Eurofyre Sales and Technical Support

    Accreditations

    ISO 9001
    UKAS Management System
    Fire Industry Association
    British Chamber of Commerce