Key Features

  • Plug & play; no need for any special tools or PC for commissioning
  • 1 or 2 loops
  • 64, 126 or 252 addresses
  • User definable zones
  • 20 Character device labels

Overview

The ProFyre A2 addressable fire alarm panel has been discontinued. Please contact us below for an alternative addressable fire alarm panel.

A compact, stylish, easy to install and configure 1 or 2 loop panel range, designed to enable installation and commissioning to take place without the need for an external PC connection.

Mounting Options

The ProFyre A2 has been designed to accommodate for many applications. Available in 3 versions; surface, semi-flush or flush.

Device Allocation

Field devices are automatically allocated to zones during final configuration by virtue of their logical address, with device text being entered using the fully integrated Qwerty keypad. An A2 panel can have up to 8 zones.

Alarm Verification

Alarm verification combined with local device alarm sounding is an established technique to reduce localised unwanted alarms affecting other occupancies, particularly in HMO’s (house in multiple occupation). Each smoke detector is therefore programmable (at the panel) and, if set to verify mode, will only raise a local alarm during the verify period chosen, prior to a full evacuation taking place. During the verification period, if the smoke or heat level drops below the alarm threshold, the affected local sandwich sounder will auto-reset and the system will return to normal without manual intervention.

ProFyre Addressable Devices

Complemented by a complete range of ProFyre addressable field devices, the ProFyre A2 is the perfect choice for systems that require straightforward alarm management and ease of use.

Wi-Fyre Compatible

For complete system flexibly, a loop powered Wi-Fyre Transponder can be connected at any point on the A2 loop wiring, enabling matching ‘wireless’ detector, call points, sounders or interfaces to be seamlessly connected to the wired system. This means that, wireless devices can now be specified and used on an ‘as-needed basis’ on a ProFyre addressable system, without the need for additional power supplies and associated wiring.

Approvals

The ProFyre A2 is fully approved by Intertek for safe use and installation in any European Union country and bears the CE mark to show that it complies with all the applicable Directives including the CPR, EMC and the Low Voltage Directive (LVD).

  • EN54-2:1997+A1:2006
    Fire detection and fire alarm systems – Control and indicating equipment.
  • EN54-4:1997+A1:2002+A2:2006
    Fire detection and fire alarm systems – Power supply equipment.

Tech Specs

ProtocolProFyre Open Protocol
Loops1 or 2 Loops (Refer to Ordering Information)
Zones 4 or 8 (Refer to Ordering Information)
Devices64, 126 or 252 (Refer to Ordering Information)
Loop Voltage 28Vdc Nominal
Loop Short Circuit Protection750mA
Loop Resistance 25 ohms (Max)
Loop Capacitance 0.3μF (Max)
Zone CapacityRecommended Maximum: 32 Devices Per Zone
PanelAuto Learn Loop Facility
Multilingual: English, Spanish, Portuguese, French, Italian
20 Zone & Device Character Sets
Sounder Synchronisation
Alarm Tone Selection
Class Change (via Interface Module)
Device Reports
One Man Test Facility
Device, Zonal & Sounder Isolation
Device Location Facility (LED Toggling)
Alarm Verification
Alarm Operation
Event Log: 2048 Events (Alarm, Fault Log)
DisplayBack-lit 4 by 20 Character Blue LCD Display
IndicationPower, Common Fire, Common Fault, Supply Fault, Earth Fault, System Fault, Loop Fault, Sounder Fault, Sounder Test, Sounder Disable, Zone 1-8 Fire, Zone 1-8 Fault, Zone 1-8 Test, Zone 1-8 Disable, General Test, General Disablement, Sounders Active, Access On
ControlsPanel Access, Start/Stop Sounders, Silence Buzzers, Reset, LED Test, Menu Navigation, Numeric Keypad Including Cancel and Enter, Keyboard Including Delete and Caps Lock, General Test, General Disablement
Outputs1 x VFCO Single Pole Fire Relay: 28Vdc @ 1A
1 x VFCO Single Pole Failsafe Fault Relay: 28Vdc @ 1A
1 x Auxiliary Relay: 24Vdc @ 1A (Spare Fused Output on PSU PCB)
1 x Repeater Output: Display Only RS485 (SELV Power Required)
1 x Printer Output: RS232 Serial
InputsClass Change: S/C Input to Start, O/C to Stop Sounders
Sounder CircuitLoop Powered Sounders Only
Mains Voltage230Vac +/- 10% @ 50/60Hz
System Voltage28Vdc Nominal (18-32V)
Charger Voltage27.6V @ 25°C (No Batteries Connected)
Total PSU Output2A
Charger Current750mA
Battery Capacity2 x 12V 12Ah SLA (Max)
Battery Cut-off VoltageLess Than 19.7Vdc
Battery Internal Resistance Limit0.9 ohm
Weight5.4kg (11.90Ibs) Excluding Batteries
Dimensions (W x H x D)375mm x 335mm x 128mm (14.76in x 13.19in x 5.03in)
Cable EntriesTop: 12 x 20mm Knockouts
Bottom: 2 x 20mm Knockouts
Rear: 2 Removable Entries, 60 x 20mm
Mounting Points3
Operating ConditionsOperating Temperature: -5° to +40°C (23°F to 104°F)
Humidity: 0% to 95% RH, non-condensing
MaterialMild Steel
ColourRAL 7035
IP RatingIP30
Design EnvironmentIndoor Use Only

Downloads

Buy

The ProFyre A2 addressable fire alarm panel has been discontinued. Please contact us below for an alternative addressable fire alarm panel.

ProFyre A2, 1 Loop, 64 Address Analogue Addressable Fire Alarm Panel

17-050
POA
Contact Us

ProFyre A2, 1 Loop, 126 Address Analogue Addressable Fire Alarm Panel

17-051
POA
Contact Us

ProFyre A2, 2 Loop, 252 Address Analogue Addressable Fire Alarm Panel

17-052
POA
Contact Us