Key Features
- Approved to EN54-2 & 4
- 8, 16, 24 zone versions
- 4 monitored sounder circuits
- Expansion of zone and sounder circuits
- Repeater panel output
Overview
The ProFyre C24 conventional fire alarm panel has been discontinued. Please contact us below for an alternative modular fire alarm panel.
A flexible, fully-featured expandable modular based conventional fire alarm control panel available in 8, 16 or 24 zone versions. The panel provides a high standard of quality and reliability that is easy to install, commission, maintain and simple to operate.
The metal enclosure can be surface or semi-flush mounted and provides excellent access during the installation and commissioning stages. 4 monitored sounder circuits and a SELV fault and fire relay are included with further expansion options for zones and sounder circuits using the modular based expansion PCB cards.
ProFyre Conventional Devices
Complemented by a complete range of ProFyre conventional field devices, the ProFyre C24 is the logical choice for systems that require clear alarm management and ease of use.
Mounting Options
The ProFyre C24 has been designed to accommodate for many applications. Available in 2 versions; surface or semi-flush.
Approvals
The ProFyre C24 is fully approved by Intertek for safe use and installation in any European Union country and bears the CE mark to show that it complies with all the applicable Directives including the CPR, EMC and the Low Voltage Directive (LVD).
- EN54-2:1997+A1:2006
Fire detection and fire alarm systems – Control and indicating equipment. - EN54-4:1997+A1:2002+A2:2006
Fire detection and fire alarm systems – Power supply equipment.
Tech Specs
Zones | 8, 16, 24 |
Device | 32 per Zone |
Zone Voltage | 21Vdc Nominal |
Zone Short Circuit Protection | 100mA |
Zone End of Line Device | 1N4002 Diode |
Manual Call Point Trigger Resistance | 470 Ohm or 680 Ohm |
Panel | Sounder Delay One Man Test Facility Zonal & Sounder Isolation |
Indication | Power, Common Fire, Common Fault, Supply Fault, Earth Fault, System Fault, General S/C, Sounder Fault Disablement, Sounder Delay, F.A.R.E Active, F.A.R.E Fault Disablement, Repeater Fault, General Disablement, General Test, Controls Active, Zone 1-24 Fire, Zone 1-24, Fault, Zone 1-24 Test/Disabled |
Controls | Panel Access, Start/Stop Sounders, Silence Buzzers, Reset, LED Test, Sounder Delay, Function, Scroll, Select |
Outputs | 1 x VFCO Fault Relay: SELV @ 1A 1 x VFCO Fire Relay: SELV @ 1A 1 x Auxiliary Output: 24Vdc @ 250mA |
Inputs | Sounder Alarm Outputs: 4 x 150mA @ 24Vdc |
Sounder Circuit | Sounder Activation Delay: 0 to 9 Minutes – In 1 Min Increments Sounder End of Line Device: 10K Resistor |
Mains Voltage | 230Vac +/- 10% @ 50/60Hz |
System Voltage | 28Vdc Nominal (19 – 32V) |
Charger Voltage | 27.6V @ 25°C (No Batteries Connected) |
Total PSU Output | 5A |
Battery Capacity | 2 x 12V 17Ah SLA (Max) |
Battery Cut-off Voltage | Less Than 20.5Vdc |
Dimensions W x H x D | 485mm x 477.5mm x 125mm (19.09in x 18.80in x 4.92in) |
Cable Entries | Top: 20 x 20mm Knockouts Bottom: 6 x 20mm Knockouts |
Mounting Points | 3 |
Material | Mild Steel |
Colour | RAL 7035 |
Operating Conditions | Operating Temperature: 0° to +50°C (32°F to 122°F) Humidity: 0% to 95% RH, non-condensing |
IP Rating | IP30 |
Design Environment | Indoor Use Only |
Downloads
Buy
The ProFyre C24 conventional fire alarm panel has been discontinued. Please contact us below for an alternative modular fire alarm panel.