Key Features

  • Factory calibrated detector
  • Integral alarm status LEDs 
  • Wireless interface: Bluetooth 4.0 (Bluetooth Low Energy) 
  • Integrates with PLCs/HVAC/BMS/FACP 
  • Configurable relays

Overview

6mm Sensepoint XCL In-Line Gas Detectors provide aspirated gas detection for use with microbore aspirating smoke detection systems. When used in conjunction with VESDA-E detectors, these inline gas detectors provide a fast and reliable warning of harmful gases that are present in the detection area.

Sensepoint in-line gas detectors are easy to install, commission and operate via an embedded Bluetooth interface that can be paired with any smart device – this allows for faster detector configuration as well as simplified operation and servicing.

These in-line gas detectors are suitable for an expansive range of applications including:

  • Residential
  • Commercial premises
  • Hospitals
  • Hotels
  • Car parks (underground / enclosed)
  • Laboratories
  • High tech manufacturing
  • Universities and schools
  • Chemical / Pharmaceutical
  • Indoor air quality monitoring
  • Battery rooms
  • Fuel storage areas
  • Confined spaces
  • Food & beverage
  • Refrigerated systems (leak detection)
  • Greenhouses

Available Sensors

There is a variety of sensor types available for 6mm Sensepoint XCL In-Line Gas Detectors including:

  • Carbon Monoxide (CO): 300ppm (adjustable 50 – 1000ppm)
  • Combustible (CAT): 0 – 100% LEL (Methane, Hydrogen, Propane, Ethanol, Butane, Octane, etc.)
  • Hydrogen (H2): 1000ppm
  • Carbon Dioxide (CO2): 5.0% v/v (adjustable 1.0 – 5.0% v/v)
  • Carbon Dioxide (CO2): 5000ppm (adjustable 1000 – 5000ppm)

How it works

VESDA 6mm Sensepoint XCL In-Line gas detectors can be added to any new or existing VESDA-E VEA installation to actively monitor the sampled air for the presence of harmful gasses. These sophisticated in-line gas detectors also integrate with other building systems such as fire alarm control panels, PLCs, HVAC and building management systems to provide real-time situational awareness for intelligent emergency response.

Sensepoint XCL detectors can detect the presence of gas in pipe lengths of up to 100m (328ft). This provides significant installation and routine maintenance cost savings with easy access to the detector unit for servicing and diagnostic information. Sensor cartridges are replaceable and can be done in the field.

Flexible Output Options

VESDA Sensepoint XCL is available with either a 4-20 mA analog output or Modbus RTU – both of which are equipped with relays. The result is a flexible solution that can be easily incorporated into legacy systems as well as new installations.

Approvals

VESDA Sensepoint XCL Gas Detectors are approved to the following standards:

  • EN/UL/IEC61010-1
  • CSA-C22.2 No. 61010- 1-12
  • EN 50270
  • RED, FCC, BT SIG
  • UL2075 (CO and CH4 ), AS 1668.2 

Tech Specs

Supply Voltage 24 VDC nominal 11 to 32V DC (Analog 4-20 mA) 9 to 32V DC (Modbus) 24V AC 50/60Hz Nominal (20 to 27 VAC)
Maximum Power Consumption (24V DC)1.2 W (Analog 4-20mA) (toxic), 1.7W (flammable and CO2 ) 0.7 W (Modbus) (toxic), 1.2W (flammable and CO2 ) Relay Version: additional 0.6W total
Maximum Inrush Current (24V DC)850 mA 
Dimensions (WxHxD)113 x 113 x 59 mm (4.4 x 4.4 x 2.3 in)
Weight500 g (1.1 lb) 
Ingress ProtectionIP65, Type 4 (NEMA 250)
Casing MaterialPolycarbonate (charcoal colour)
Operating Temperature:−20 to +50 °C (−4 to +122 °F)
Storage Temperature0 to +30 °C (+32 to +86 °F)
Humidity0 to 99% (non-condensing) Flammable catalytic versions: 10 to 90% RH. Operating the detector outside this range may result in increased drift and a reduction in detector accuracy.
Atmospheric pressure95 to 110 kPa
Wire/Terminal sizePluggable rising clamp style. 0.5 to 1.5 mm2 , 20 to 16 AWG.
OutputAnalog Output: 0 to 22 mA Digital Output: Modbus RTU Relay Output: 2 relays (24 V DC / 240 V AC, 5 A)

Downloads

Buy

Eurofyre is an authorised distributor of Honeywell and has been a major technical wholesaler of Xtralis products since 2007. We offer expert advice and supply all aspects of VESDA, FAAST and ICAM aspirating smoke detection systems including pipework calculations, demonstration/training and excellent after-sale support.

Contact us to receive competitive trade discounts or apply online for a credit account.

VESDA Sensepoint XCL, 6mm, Flammable (CAT, 4-20mA Analogue, Relay

XCL-VEA-CH4-RA
POA
Contact Us

VESDA Sensepoint XCL, 6mm, Flammable (CAT), Modbus RTU, Relay

XCL-VEA-CH4-RM
POA
Contact Us

VESDA Sensepoint XCL, 6mm, Carbon Monoxide, 4-20mA Analogue, Relay

XCL-VEA-CO-RA
POA
Contact Us

VESDA Sensepoint XCL, 6mm, Carbon Monoxide, Modbus RTU, Relay

XCL-VEA-CO-RM
POA
Contact Us

VESDA Sensepoint XCL, 6mm, Carbon Dioxide (ppm), 4-20mA Analogue, Relay

XCL-VEA-CO2PP-RA
POA
Contact Us

VESDA Sensepoint XCL, 6mm, Carbon Dioxide (ppm), Modbus RTU, Relay

XCL-VEA-CO2PP-RM
POA
Contact Us

VESDA Sensepoint XCL, 6mm, Carbon Dioxide (% v/v), 4-20mA Analogue, Relay

XCL-VEA-CO2VV-RA
POA
Contact Us

VESDA Sensepoint XCL, 6mm, Carbon Dioxide (% v/v), Modbus RTU, Relay

XCL-VEA-CO2VV-RM
POA
Contact Us

VESDA Sensepoint XCL, 6mm, Hydrogen, 4-20mA Analogue, Relay

XCL-VEA-H2-RA
POA
Contact Us

VESDA Sensepoint XCL, 6mm, Hydrogen, Modbus RTU, Relay

XCL-VEA-H2-RM
POA
Contact Us